Root Blowers are the most suitable type of blowers for aquaculture applications. Their rugged construction and heavy twin lobes can resist water head and so continue to give good air flow even at water depths of 2 mtr. and more. They are available in sizes of 3 HP and above.

TECHNICAL DATA FOR 5 HP BLOWER

MODEL RIC–014(5HP)
CONSTRUCTION CI
COOLING AIR COOLED
FLOW HORIZONTAL
CAPACITY 300 M3/HR
PRESSURE 0.3 KG/ CM2
BLOWERRPM 1933 RPM
REC.POWER 5HP / 1450 RPM
DRIVE V BELT DRIVE

TECHNICAL DATA FOR 7.5 HP BLOWER

MODEL RIC–016(7.5HP)
CONSTRUCTION CI
COOLING AIR COOLED
FLOW HORIZONTAL
CAPACITY 400 M3/HR
PRESSURE 0.3 KG/ CM2
BLOWERRPM 1700 RPM
RECOMMENDED POWER 7.5HP / 1450 RPM
DRIVE V BELT DRIVE

TECHNICAL DATA FOR 10 HP BLOWER

MODEL RIC–016(10HP)
CONSTRUCTION CI
COOLING AIR COOLED
FLOW HORIZONTAL
CAPACITY 500 M3/HR
PRESSURE 0.3 KG/ CM2
BLOWERRPM 2000 RPM
RECOMMENDED POWER 10HP / 1450 RPM
DRIVE V BELT DRIVE

TECHNICAL DATA FOR 15 HP BLOWER

MODEL RIC–019(15HP)
CONSTRUCTION CI
COOLING AIR COOLED
FLOW HORIZONTAL
CAPACITY 800 M3/HR
PRESSURE 0.3 KG/ CM2
BLOWERRPM 1900 RPM
RECOMMENDED POWER 15HP / 1450 RPM
DRIVE V BELT DRIVE

TECHNICAL DATA FOR 20 HP BLOWER

MODEL RIC–020(20HP)
CONSTRUCTION CI
COOLING AIR COOLED
FLOW HORIZONTAL
CAPACITY 1000 M3/HR
PRESSURE 0.3 KG/ CM2
BLOWERRPM 1900 RPM
RECOMMENDED POWER 20HP / 1450 RPM
DRIVE V BELT DRIVE

MACHINE OF CONSTRUCTION

ROTOR PAIR SG IRON
CASING (BODY) CI-IS210 FG260
COVERS CI-IS210 FG260
OUTER COVERS CI-IS210 FG260
GEAR PAIR Alloy steel / Hardened & Ground
BEARINGS ZKL/SKF

FOLLOWING ACCESSORIES INCLUDED

Suction Silencer Suction filter
V pulley for Machine & Motor Base frame with slide rail
Pressure gauge T connection for pipe fitting
V belt set Belt guard
Tire mounting assembly flame

TERMS & CONDITIONS

Price Ex-our works unpacked
Taxes 18% GST Applicable extra
Packing 3% Extra
Freight To pay basis
Delivery Within 1 week after receipt of your Techno-commercially Clear PO order.
Payment 100% advance
Validity 30 days
Insurance Your scope, however can be arranged at extra cost @1%

Detailed explanation of Flow parameters

Air Flow – Depends on blower size and output. At 2 PSI pressure and 1 mtr water head, Average flow rate per mtr is approximately 500 ltrs/ hour (0.5 m3 / hr). However since bursting is not a concern, the air flow can increase as high as required by increasing blower and motor size. This is not however useful for aeration purpose since the flow will be too high to have any meaningful dissolution of air.
Bubble size – varies with depth of installation and blower pressure. At 1.5 mtr depth, bubble size at exit of tube is less than 1 mm, at a pressure of 2.0 PSI. However it will change depending on salinity, air flow from blower, pressure, water depth, etc.

Warrantee :- 12 months from the date of dispatch against any manufacturing defects, faulty workmanship, defective material. However, this warranty is not applicable in case of normal wear and tear or due to hazardous materials, environment or due to any other cause which is beyond our controls.