Turbine blowers are light, easy to install and operate at high rpm. However they are useful only in shallow water depths, at most upto 1 mtr. And the ratio of blower HP to AirOxi tube is also reduced. But their light construction and ease of installation makes them ideal for hatcheries and small ponds.
TECHNICAL DATA FOR 5 HP BLOWER
MODEL | AOTBL – 0.5 HP |
---|---|
CONSTRUCTION | Cast Aluminum |
COOLING | AIR COOLED |
FLOW | HORIZONTAL |
DISPLACEMENT | 80 M3/ HR |
PRESSURE | 140 mbar / 0.14 Kg/cm2 |
BLOWER RPM | 2800 RPM |
MOTOR. Option of single or 3 phase | 0.5 HP / 2800 RPM |
DRIVE | Direct Shaft |
Model – AOTBL – 1.0 HP
MODEL | AOTBL – 1.0 HP |
---|---|
CONSTRUCTION | Cast Aluminum |
COOLING | AIR COOLED |
FLOW | HORIZONTAL |
DISPLACEMENT | 145 M3/ HR |
PRESSURE | 140 mbar / 0.14 Kg/cm2 |
BLOWER RPM | 2800 RPM |
MOTOR. Option of single or 3 phase | 1.0 HP / 2800 RPM |
DRIVE | Direct Shaft |
Model – AOTBL – 1.5 HP
MODEL | AOTBL – 1.0 HP |
---|---|
CONSTRUCTION | Cast Aluminum |
COOLING | AIR COOLED |
FLOW | HORIZONTAL |
DISPLACEMENT | 210 M3/ HR |
PRESSURE | 170 mbar / 0.17 Kg/ cm2 |
BLOWERRPM | 2800 RPM |
MOTOR. Option of single or 3 phase | 1.5 HP / 2800 RPM |
DRIVE | Direct Shaft |
OPTIONAL ACCESSORIES
Non Return Valve
5 mtr wire connected to the motor
TERMS & CONDITIONS
Price | Ex-our works unpacked |
Taxes | 18% GST Applicable extra |
Packing | 2% Extra |
Freight | To pay basis |
Delivery | Within 1 week after receipt of your Techno-commercially Clear PO order. |
Payment | 100% advance |
Validity | 30 days |
Insurance | Your scope, however can be arranged at extra cost @1% |
Warrantee :-12 months from the date of dispatch against any manufacturing defects, faulty workmanship, defective material. However, this warranty is not applicable in case of normal wear and tear or due to hazardous materials, environment or due to any other cause which is beyond our controls.
Correct wiring of the motor is the customer’s responsibility. Output wires from the motor will be provided upon request. However correct wiring to the plug is the customers’ responsibility. The motor is not covered under warranty for improper wiring. Or for input power issues like voltage fluctuation or phase related issues, or generator issue, etc.
Usage instructions for better results
- Since the pipe already has holes, there is no burst pressure that can be calculated, but for theoretical / test purposes we can consider burst pressure to be 4 to 8 Kg/ cm2 depending on the size used
- Maximum recommended length of installation per tube – 25 feet Recommended distance between each tube in the pond – 10 to 20 feet when installed in long lines or rings and 4 inches when installed as grids
- Quantity of pipe used depends on blower size. If you use less pipe then required for the blower, it will put load on the blower