Turbine blowers are light, easy to install and operate at high rpm. However they are useful only in shallow water depths, at most upto 1 mtr. And the ratio of blower HP to AirOxi tube is also reduced. But their light construction and ease of installation makes them ideal for hatcheries and small ponds.

TECHNICAL DATA FOR 5 HP BLOWER

MODEL AOTBL – 0.5 HP
CONSTRUCTION Cast Aluminum
COOLING AIR COOLED
FLOW HORIZONTAL
DISPLACEMENT 80 M3/ HR
PRESSURE 140 mbar / 0.14 Kg/cm2
BLOWER RPM 2800 RPM
MOTOR. Option of single or 3 phase 0.5 HP / 2800 RPM
DRIVE Direct Shaft

Model – AOTBL – 1.0 HP

MODEL AOTBL – 1.0 HP
CONSTRUCTION Cast Aluminum
COOLING AIR COOLED
FLOW HORIZONTAL
DISPLACEMENT 145 M3/ HR
PRESSURE 140 mbar / 0.14 Kg/cm2
BLOWER RPM 2800 RPM
MOTOR. Option of single or 3 phase 1.0 HP / 2800 RPM
DRIVE Direct Shaft

Model – AOTBL – 1.5 HP

MODEL AOTBL – 1.0 HP
CONSTRUCTION Cast Aluminum
COOLING AIR COOLED
FLOW HORIZONTAL
DISPLACEMENT 210 M3/ HR
PRESSURE 170 mbar / 0.17 Kg/ cm2
BLOWERRPM 2800 RPM
MOTOR. Option of single or 3 phase 1.5 HP / 2800 RPM
DRIVE Direct Shaft

OPTIONAL ACCESSORIES

Non Return Valve
5 mtr wire connected to the motor

TERMS & CONDITIONS

Price Ex-our works unpacked
Taxes 18% GST Applicable extra
Packing 2% Extra
Freight To pay basis
Delivery Within 1 week after receipt of your Techno-commercially Clear PO order.
Payment 100% advance
Validity 30 days
Insurance Your scope, however can be arranged at extra cost @1%
Warrantee :-12 months from the date of dispatch against any manufacturing defects, faulty workmanship, defective material. However, this warranty is not applicable in case of normal wear and tear or due to hazardous materials, environment or due to any other cause which is beyond our controls.
Correct wiring of the motor is the customer’s responsibility. Output wires from the motor will be provided upon request. However correct wiring to the plug is the customers’ responsibility. The motor is not covered under warranty for improper wiring. Or for input power issues like voltage fluctuation or phase related issues, or generator issue, etc.

Usage instructions for better results

  • Since the pipe already has holes, there is no burst pressure that can be calculated, but for theoretical / test purposes we can consider burst pressure to be 4 to 8 Kg/ cm2 depending on the size used
  • Maximum recommended length of installation per tube – 25 feet Recommended distance between each tube in the pond – 10 to 20 feet when installed in long lines or rings and 4 inches when installed as grids
  • Quantity of pipe used depends on blower size. If you use less pipe then required for the blower, it will put load on the blower

Get in Touch